DC3021 G.703/X.21 Converter
Specifications

Interfaces
  • Network G.703 – 2 ΄ BNC for unbalanced (75W) 1 ΄ RJ45 socket for 120W balanced
  • Equipment X.21 – 15 way ‘D’ type socket
  • LEDs
    Line:
    • Green valid HDB3 data present
    • Red- no valid HDB3 data present
    • Yellow ( flash) –Bipolar Violations
    Loop:
    • Yellow (Flash)- unit in Loopback
Loop Enable Sequence (via network interface)
  • The unit requires to see the pattern ‘00001’ repeated solidly without error for a minimum of 5 seconds before the loopback circuitry is activated.
Loop Disable Sequence (via network interface)
  • The unit requires to see the pattern ‘001’ repeated solidly without error for a minimum of 5 seconds before the loopback circuitry is disabled.

    The Loopback circuitry can also be disabled either by a loss of power to the unit or by a loss of Network line signal for more than 5 seconds
Power:
  • Input voltage 5VDC – 2.1mm jack socket, tip +ve 220/240VAC at 45-65Hz
  • Consumption 2W max, Supplied with either UK (3 pin) or European (2pin) lump plug
  • PSUs – specify at time of order
  • Size:- 85 ΄ 37 ΄ 145mm (W ΄ H ΄ L)


For further information please contact us