DC3021 G.703/X.21 Converter Specifications
- Network G.703 2 ΄ BNC for unbalanced (75W) 1 ΄ RJ45 socket for 120W balanced
- Equipment X.21 15 way D type socket
- LEDs
Line:- Green valid HDB3 data present
- Red- no valid HDB3 data present
- Yellow ( flash) Bipolar Violations
Loop: - Yellow (Flash)- unit in Loopback
- The unit requires to see the pattern 00001 repeated solidly without error for a minimum of 5 seconds before the loopback circuitry is activated.
- The unit requires to see the pattern 001 repeated solidly without error for a minimum of 5 seconds before the loopback circuitry is disabled.
The Loopback circuitry can also be disabled either by a loss of power to the unit or by a loss of Network line signal for more than 5 seconds
- Input voltage 5VDC 2.1mm jack socket, tip +ve 220/240VAC at 45-65Hz
- Consumption 2W max, Supplied with either UK (3 pin) or European (2pin) lump plug
- PSUs specify at time of order
- Size:- 85 ΄ 37 ΄ 145mm (W ΄ H ΄ L)
For further information please contact us
|